Compatibility Table for Virex Pro / Phoenix Software

All versions of UFH Firmware and PC Client within one color band are compatible among themselves.

When updating from an older version to a newer one, the parameters of all parameter changes in between have to be reconfigured.

Date UFH
Firm-
ware
Version
PC
Client
Version
Parameter Changes
2012-11-27 3.29r1 3.22r0
2012-11-07 3.29r0 3.21r1
2012-10-24 3.28r1

2012-10-17 3.28r0 3.21r0
  • CEBW:
    • Raised maximum value for parameter "number of backwashes before CEBW" from 1000 to 100000. This moved the parameter to a new EEPROM address.

    NOTE: Since the size of the EEPROM variable for storing the current number of performed BWs has changed, the whole production data (process data) will be invalidated upon first system start. This will have the following impacts:
    • Membrane fouling level thresholds for the LEDs will be incorrect. If you wish to correct this, you would have to do one of the two possibilities from the menu on the ECU: Either "Reset permeability" or "New filter".
    • Data concerning performed DIT (timestamp, measured Q_P) will be incorrect until next DIT. This will correct itself upon the next DIT.
2012-10-04 3.27r2

2012-07-13 3.27r1

2012-04-30 3.27r0

2012-04-24 3.26r0 3.20r0
  • CEBW:
    • Raised maximum value for parameter "number of backwashes before CEBW" from 1000 to 100000. This moved the parameter to a new EEPROM address.

    NOTE: Since the size of the EEPROM variable for storing the current number of performed BWs has changed, the whole production data (process data) will be invalidated upon first system start. This will have the following impacts:
    • Membrane fouling level thresholds for the LEDs will be incorrect. If you wish to correct this, you would have to do one of the two possibilities from the menu on the ECU: Either "Reset permeability" or "New filter".
    • Data concerning performed DIT (timestamp, measured Q_P) will be incorrect until next DIT. This will correct itself upon the next DIT.
2012-04-16 3.25r4

2012-04-04
3.19r2
2012-03-02 3.25r3

2012-02-27 3.25r2 3.19r1
2012-02-02 3.25r0 3.19r0
  • Global:
    • Changed default value of "max. TMP at BW" from 8 bar to 5 bar.
    • Added new parameter "CheckValveInFeed (0 = none, 1 = exists)"
  • DIT:
    • Changed max. value of "de-aeration time" from 300 s to 600 s.
2011-12-14 3.24r1

2011-10-11 3.24r0 3.18r0 Additional state name for new state StartInternalBW1.
2011-08-30 3.23r1 3.17r3
2011-08-16 3.23r0 3.17r2
2011-08-08 3.22r3 3.17r1
2011-07-29 3.22r2 3.17r0
2011-07-05 3.22r1 3.16r1
2011-06-09 3.21r3 3.16r0
2011-06-09 3.21r2

2011-06-06 3.21r1

2011-05-31 3.21r0 3.15r0
2011-05-23 3.20r0 3.14r0
  • Alarm:
    • External alarm reaction
2011-05-02 3.19r1

2011-04-28 3.19r0

2011-04-21 3.18r0 3.13r0
  • Global:
    • StateOnCanHeartbeatLoss
    • MaxCanHeartbeatLossTime_s
2011-04-12
3.12r0
2011-04-04 3.17r2

2011-03-24 3.17r1

2011-03-16 3.17r0 3.11r1
  • Global:
    • Temperature in °C
2011-03-15 3.16r0 3.11r0
  • Alarm:
    • External alarm reaction
2011-03-11 3.15r5

2011-03-10 3.15r4 3.10r6
2011-03-02 3.15r3 3.10r5
  • Integrity test:
    • new: BP_max
    • new: p_test_minus_BP_max
    • new: dp_test_time
    • modified: testDuration
2011-02-01 3.15r0 3.10r4
  • Global:
    • No flush or DIT while filtrating
2011-01-28
3.10r3
2011-01-27 3.14r0 3.10r2
  • Data logger configuration
  • Global:
    • logging interval
    • p1 logging threshold
  • DIT:
    • p_test
    • IntegritytestPressureThresholdAdcValueForSwitchOn
    • Nephelometer4mATurbidityValue
    • Nephelometer20mATurbidityValue
    • D_base
    • ALCR
    • VCF
    • Q_p
    • V_sys
    • turb_UCL
2011-01-14 3.13r0 3.10r1
  • Main menu items
  • Integrity test
  • SMS configuration
  • Other strings
  • Feed pump
  • Global: logging interval
2010-10-28 3.10r0

2010-10-27 3.09r2 3.09r2
2010-08-11 3.09r1

2010-08-04
3.09r1
2010-07-05 3.09r0 3.09r0
2010-06-24 3.08r0 3.08r0 New main menu item "Chemical flush".
2010-05-18 3.07r0 3.07r0 New "Global" parameters:
  • flow rate display unit
  • pressure display unit
2010-04-26
3.06r1
2010-04-23 3.06r0 3.06r0
  • Inserted 2 new main menu items
    • "New filter" and
    • "Reset Q/dp"
    before the existing main menu items
    • "Set system No.",
    • "Spare mode", and
    • "About".
    The latter 3 main menu items therefore are shifted in their positions by 2.

  • Added 4 new "other stings" to the parameters:
    • Q_dp_resetted (default: "Q/dp zurueckgesetzt")
    • NotAllowed (default: "nicht zulaessig!")
    • MinQ (default: "min. Q")
    • CalibAt (default: "kalib. bei")
2010-04-21 3.05r0 3.05r0 New filtration parameters:
  • Fill level monitoring (0: NONE, 1: FILTRATE, 2: FEED), default: 0
  • signal of fill level sensor when empty in mA, default:  3,99 mA
  • signal of fill level sensor when full in mA, default: 19,98 mA
  • lower spare mode filtrate fill level in %, default: 90 %
  • upper feed pump stop feed fill level in %, default:  5 %
  • min. feed fill level in % for flushing,    default: 10 %
2010-04-12 3.04r0 3.04r0
2010-03-23 3.03r1

2010-03-19 3.03r0 3.03r0
  • Added new parameter "Close feed valves while another UFH flushes" to the global parameters (only visible in developer mode).
  • Changed alarm parameter TestExternalAlarm [NO, YES] to ExternalAlarmReaction [NONE, STOP, SPARE].
2010-01-29 3.02r0 3.02r0
2009-11-27 3.01r0 3.01r0
  • Moved the parameter minimumFiltrationPeriod from the filtration parameters to the flush parameters
  • Neuer Spülparameter: Maximale Filtrationsdauer bei verschmutzungsabhängiger Spülung
2009-11-18 3.00r0 3.00r0 Neuer globaler Parameter: Automatischer täglicher Reset
2009-10-08 2.22r0 2.22r0
  • Changed the default values of the following parameters to the following new values:

    • Main menu item "node ID": "UF-Anlagen-Nr."
    • State name "Reinigung1": "Hole Exklusivitaet"
    • State name "MemTest1": "Hole Exklusivitaet"
    • State name "StartBackwash5": "Zulaufventil 1 auf"
    • State name "StartBackwash6": "Zulaufventil 2 auf"
    • State name "Chem. BW 1": "Chem. BW 1"
    • Spare mode flush cycle: 720 min
    • Min. filtration duration: 20 min
    • Threshold for fouling depended flush: 90 %
    • Flush type: Interval + fouling depended
    • Flush interval duration: 3 h
    • Min. permeability after flush: 50 %
  • Added the state names SetValvesBwF1OpenV1, SetValvesBwF1OpenV3, Dispensing8.1, and Dispensing8.2 and removed Chem.BW2.
    -> Therefore all the state names from Chem.BW3 on until the end of the list are shifted in their positions.

2009-07-27 2.21r0 2.21r0
  • Neuer Zustandsname "SpareMode".

  • Neuer Menüpunkt "Spare Mode".

  • Neuer Spülparameter "Reservebetrieb-Spülzyklus".

2009-07-15 2.20r0 2.20r0
  • Das interne Datenlog-Format hat sich geändert und ist nicht kompatibel zum Vorgängerformat.
    Falls der bestehende Datenlog „gerettet“ werden soll, muss dieser vor dem Update noch mit der Vorgängerversion ausgelesen werden.

  • Die Zustände Integritytest1 und Reinigung1 haben neue Default-Texte bekommen.
    Die Texte im Speicher der UFH sollten auch angepasst werden.

  • Da das Menü um einen Menüpunkt erweitert wurde, müssen die Menütexte angepasst werden.

  • Neuer globaler Parameter "Periphäre Eingänge via CAN".
  • Bei dieser Version könnte die TCP-Verbindung nicht korrekt funktionieren, da sich diese gerade im Umbau befindet.

2009-07-02
2.19r8
2009-07-01
2.19r7
2009-06-24
2.19r6
2009-05-29 2.19r3 2.19r5 Kommunikation > Modem > TCP Communication Parameters...
2009-05-11
2.19r4
2009-05-11
2.19r1
2009-05-06 2.19r2 2.19r0 Neue Parameter unter Kommunikation > Modem > TCP Communication Parameters...
2009-04-21
2.18r1
2009-04-21 2.19r1 2.18r0 Neue Parameter für internes Modemmodul.
2009-03-02 2.18r6 2.17r2
2009-02-27 2.18r5 2.17r1
2009-02-18 2.18r4

2009-02-18 2.18r3

2009-02-17 2.18r2 2.17r0